Wireless High Low Voltage Clamp Meter Online AC Current Tester
Characteristic
- Range: 0.1mA~1000A
- Accuracy: 0.1Ma
- Circuit Voltage: below 60KV (operated with insulation rod)
- Transmission: wireless Transmission-30m
- 11 years of specialized meters
- OEM services available
- ISO,Patent and CE certificate
- igh temperature resistance
- high and low voltage changing ratio tester
- Impact resistance
- High insulation and scalability
- Bending resistance
- Insulation rod has the characteristics of moisture resistance
- 30m Wireless transmission
- Wide range
- High voltage AC current measurement, low voltage AC current, current leakage measurement, online AC current measurement
- Peak value Hold
Specifications
Function | High voltage AC current measurement, low voltage AC current, current leakage measurement, online AC current measurement |
Power Supply | DC6V alkaline dry battery(1.5V AAA×4) |
Test Mode | Clamp CT, integral approach |
Transmission Mode | Wireless transmission, the maximum distance of straight line transmission is about 30m |
Display Mode | 4 bit LCD display, with backlight function |
LCD Dimension | 47mm×28.5mm |
Meter Dimension | Width, height, thickness: 76mm×255mm×31mm |
Clamp Dimension | 48mm |
Sampling Rate | 2 times/second |
Measurement Scope | 0.0mA~1000A (50/60Hz automatic) |
Resolution | 0.1mA |
Shift | 0.0mA~1000A automatic shift |
Accuracy
(23℃±5℃, below 70%RH)
|
0.0mA~299mA: ±1%±3dgt |
0.30A~9.99A: ±1.5%±5dgt | |
10.0A~199.9A: ±2%±5dgt | |
200A~399A: ±2.5%±5dgt | |
400A~600A: ±3%±5dgt | |
601A~1000A: ±4%±5dgt | |
Line Voltage | Below 60KV line test (with 5 insulation rods operation) |
Data Memory | 99 sets, memory process is shown by MEM , full storage is shown by blinking “FULL” |
PEAK value maintaining | Automatically maintain the high test value, in usual testing mode, press key HOLD till the lighting of PEAK, that is, start PEAK to maintain this function. |
Data Hold | In usual testing mode, press HOLD key to keep data, shown by “HOLD” |
Data Access | “MR” indication, can access to all data |
Overflow Display | Over-range overflow function: shown in “OL A” |
No Signal Indication | “no- –” is shown when receiver does not receive the dynamic display of signal transmission |
Automatic Shutdown | 15 minutes after boot |
Battery Voltage | When battery voltage is lower than 4.8V, battery voltage is shown in low symbol to remind battery replacement |
Meter mass | Detector: 335g (with battery), the total mass of meter: 2.5kg (including insulation rod and battery) |
Working Temperature and Humidity | -25℃~40℃; below 80%Rh |
Storage Temperature and Humidity | -10℃~60℃; below 70%Rh |
Insulation Rod Dimension | φ32mm, 1m/piece (5pieces) |
Insulation Strength | AC 100kV/rms (between the 5th insulation rod and high voltage current clamp core) |
Structure | Anti-drip type Ⅱ |
Safety Provisions | IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ(600V), IEC61326(EMC standard) |
Accessories | Clamp: 1 piece; receiver: 1 piece; meter box: 1 piece; insulation rod (1m): 5 pieces; battery (alkaline battery AAA): 8 pieces |