NDIR CO2 Flue gas analyser ECDO2 CO SO2 NO2 NO
2. NDIR-technology to measure CO high, CO2 and HC.
3. Maximum measure 9 gases: six ECD sensors and three NDIR sensors.
4. Auto ZERO function.
5. Built-in pump.
6. Calculation of Lambda and combustion efficiency.
7. LCD 320 x 240 display and RS232 digital output.
Measurement Components | SO2,NO,CO,CO2,O2; flue gas temperature |
Measurement technology | CO2:NDIR: CO/O2/SO2/NO:ECD
flue gas temperature:K-type thermocouple |
Measurement Range | SO2/NO: (0~:2000) ppm; CO:(0~5000) ppm:CO2/O2:(0~25)% |
Accuracy | CO/CO2/SO2/NO/O2:±2%F.S.;flue g as temperature:±3℃ |
Resolution | SO2/NO/CO:1ppm; CO2/O2:0.01% |
Repeatability | ≤2% |
Response time | T90<20s (NDIR) |
Flowrate | (0.7~1.2) L/min |
Output | RS485/RS232 |
Power supply | Built-in rechargeable lithium bat |